• / 24
  • 下载费用:10 金币  

源文件编程和用户文件的重新接线

关 键 词:
源文件编程和用户 文件和源文件
资源描述:
Date:* File:SSP2_02C.1 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 源文件编程和用户程序的重新接线 “什么是 口令? ” Date:* File:SSP2_02C.2 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 编程工具 PRGG_T2DPRGG_T2D Date:* File:SSP2_02C.3 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 利用文本编辑器生成程序 Date:* File:SSP2_02C.4 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 启动文本编辑器 Date:* File:SSP2_02C.5 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 编辑一个源文件 (1) 被编辑的源文件 块样板 块 文件 文件 插入块样板 插入块 插入文件 插入文件 产生 Date:* File:SSP2_02C.6 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 编辑一个源文件 (2) UDT 全局 DB UDT型 DB FB3 FB3的背景 DB FC5 OB1 分配给 调用 调用 调用 调用 分配给 Date:* File:SSP2_02C.7 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 代码块的语法 Date:* File:SSP2_02C.8 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 数据块的语法 Date:* File:SSP2_02C.9 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 变量声明 Date:* File:SSP2_02C.10 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 保护属性 Date:* File:SSP2_02C.11 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 保存, 一致性检查和编译 Date:* File:SSP2_02C.12 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 练习2.1: 利用源文件将FC转换为FB (1) Date:* File:SSP2_02C.13 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 练习2.1: 利用源文件将FC转换为FB (2) : : : : Date:* File:SSP2_02C.14 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 程序重新接线简介 信号模板 前连接器 失效的通道 I 16.7 可用的通道 I 17.0 A I 16.7 . . . . AN I16.7 “旧” 程序 A I 17.0 . . . . AN I17.0 “新” 程序 Date:* File:SSP2_02C.15 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 用SIMATIC管理器实现重新接线 Date:* File:SSP2_02C.16 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 概述:用源程序实现重新接线 带符号地址的 STEP 7 程序 “Blocks” 文件夹 “Source Files” 文件夹 带符号地址的 源程序 1 符号表 (旧) 符号表 (新) 2 “Blocks” 文件夹 重新接线的 带符号地址的 STEP 7 程序 3 Date:* File:SSP2_02C.17 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 从已有的S7程序产生源程序 Date:* File:SSP2_02C.18 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 生成的源程序 Date:* File:SSP2_02C.19 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 符号表:改变绝对地址 之前 之后 Date:* File:SSP2_02C.20 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 重新接线的结果 FC 5 “旧” FC 5 “新” Date:* File:SSP2_02C.21 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 用“符号优先”重新接线 Date:* File:SSP2_02C.22 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 练习2.2:用SIMATIC 管理器实现重新接线 步骤操作结果 1 在SIMATIC管理器中,从项目“STOE_32” 下将S7程序REWIRE拷贝到“My Project”项目 下 一个名为“REWIRE”的S7程序被存在 项目“My Project”中。 在S7程序“REWIRE”中,单击“Blocks”对象对象被选中。2 选择菜单命令 Options - Rewire. 弹出“重新接线”窗口。3 在旧地址中输入I 8.0,在新地址中输入I 9.0, 用“OK”钮确认 S7 程序“REWIRE”被修改成新地址。4 从S7 程序“REWIRE”打开符号表,把符号 LB1的地址从 I 8.0 换成 I 9.0。 保存符号表并退出符号编辑器。 符号LB1被分配一个新地址。5 利用交叉参考表检查重新接线是否成功。I 9.0替换程序中原来的 I 8.0。 6 Date:* File:SSP2_02C.23 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 修改扫描 2x Date:* File:SSP2_02C.24 SIMATIC S7 Siemens AG 2000. All rights reserved. Information and Training Center Knowledge for Automation 练习2.3:修改扫描 为安全起见,采用常闭触点 (NC) 停止设备。当出现断线或接地故障时, 这个开关停止设备运行。 程序中的对信号“1”的扫描必须用对信号“0”的扫描代替。
展开阅读全文
  麦档网所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
0条评论

还可以输入200字符

暂无评论,赶快抢占沙发吧。

关于本文
本文标题:源文件编程和用户文件的重新接线
链接地址:https://www.maidoc.com/p-15663108.html
关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

[email protected] 2018-2020 maidoc.com版权所有  文库上传用户QQ群:3303921 

麦档网为“文档C2C模式”,即用户上传的文档所得金币直接给(下载)用户,本站只是中间服务平台,本站所有文档下载所得的金币归上传人(含作者)所有。
备案号:蜀ICP备17040478号-3  
川公网安备:51019002001290号 


收起
展开